2.2 Top View
The top panel of the 5073E-T Switch includes two terminal block connectors. One terminal block has two DC power
inputs and one fault alarm, and the other has two digital inputs (DI) and two digital outputs (DO).
Figure 4 Top Panel of 5073E-T Switch
2.3 LED Indicators
The diagnostic LEDs are located on the front panel of the industrial switch and provide real-time information about
the system. The following table describes each LED state.
LED Color State Description
Pwr
Green On The switch unit is powered on
Off No power
R.Master
Green On The switch is a master in Pro-Ring2se group
Off The switch is a slave in Pro-Ring2se group, or Pro-Ring2se is
disabled
Pwr1
Green On Power 1 is active
Off Power 1 is inactive
Pwr2
Green On Power 2 is active
Off Power 2 is inactive
Fault
Red On Power or port failure
Blinking Location alert
Off No failure