CLI Commands Level Description Example
alias
[name]
I Set port alias name. switch>enable
switch#configure
switch(config)#interface fastEthernet 2
switch(config-if)#alias 1111
show interface
configuration
I Show interface configuration status. switch>enable
switch#configure
switch(config)#interface fastEthernet 2
switch(config-if)#show interface
configuration
Port Monitoring Commands
CLI Commands Level Description Example
monitor destination
[RX|TX|Both]
I Configure destination port of monitor. switch>enable
switch#configure
switch(config)#interface fastEthernet 2
switch(config-if)#monitor destination
rx
monitor source
[RX|TX|Both]
I Configure source port of monitor. switch>enable
switch#configure
switch(config)#interface fastEthernet 2
switch(config-if)#monitor source rx
show monitor P Show port monitor information. switch>enable
switch#show monitor
show monitor I Show port monitor information. switch>enable
switch#configure
switch(config)#interface fastEthernet 2
switch(config-if)#show monitor
no monitor I Disable source port of monitor. switch>enable
switch#configure
switch(config)#interface fastEthernet 2
switch(config-if)#no monitor
Port Security Commands
CLI Commands Level Description Example
mac-address-table static
hwaddr
[HW-Addr]
I Configure the MAC address entry of
the interface (static).
switch>enable
switch#configure
switch(config)#interface fastEthernet 2
switch(config-if)#mac-address-table
static hwaddr 000012345678
show mac-address-table
static
P Show MAC address table (static). switch>enable
switch#show mac-address-table
static